GloMax®-Multi+ Microplate
with Instinct® Software
|
GloMax®-Multi Jr
Single Tube
|
| |
|
|
| Catalog No. |
E8032 with Shaking
E9032 with Heating and Shaking |
E6070 Base Instrument
E6080 Instrument with Luminescence Installed |
| Product Type |
6-384-well Microplate Multimode Reader |
Single Tube Multimode Reader |
| Description |
Versatile Microplate Reader with Shaking, Instinct® Software, and Optional Heating.
[Read More] |
Multifunctional single tube instrument for utmost flexibility.
[Read More] |
| Available Detection Modes |
Luminescence:
E8041 Luminescence
Fluorescence:
E8051 Fluorescence
Absorbance:
E8061 Visible
E9061 UV Visible |
Luminescence:
E6098 Luminescence (or installed in instrument E6080)
Fluorescence:
E6071 Blue
E6072 UV
E6073 Green
E6074 Red
E6075 GFPUV
Absorbance:
E6076 Absorbance Module. Add 1 or more filter paddle(s):
E6077 560nm Filter
E6078 600nm Filter
E6079 750nm Filter |
| Read Type |
Glow, Flash, Kinetic, Repeat |
Glow, Kinetic, Repeat |
| Sample Format |
6, 12, 24, 48, 96, 384-well plates |
10 x 10 mm cuvette, 100 - 200 µl minicell vial (optional), 0.5 ml PCR tube (optional, fluorescence), 1.5 ml microcentrifuge tube (Luminescence) |
| Shaking |
Four speeds (150, 300, 500 rpm, Variable) linear and orbital modes |
Not Available |
| Temperature Control |
Optional: 2° C above ambient temperature to 45° C +/- 0.75° C |
Not Available |
| Injectors |
Optional:
E7071 Single Injector
E7081 Dual Injectors
Selectable between 25 - 200 µl in 5 µl increments for 6 to 96-well plate formats. |
Not Available |
| Detector |
Head-on photomultiplier tube (PMT) for photon-counting |
Photomultiplier tube (PMT) |
| Detection Limit |
3 x 10-21 moles of Luciferase or 1 x 10-18 moles of ATP |
1 x 10-16 moles ATP or 1 x 10-20 moles of Luciferase |
| Linear Dynamic Range |
> 8 logs |
5 logs |
| Crosstalk |
5 x 10-5 |
Not Applicable |
| Sample Adapter |
Not Applicable |
Optional. Holds 1.5 ml microcentrifuge tubes |
| Spectral Range |
350 - 650 nm |
350 - 650 nm |
| Peak Wavelength |
420 nm |
420 nm |
| Light Source |
Wavelength-matched LED |
Wavelength-matched LED |
| Detector |
PIN-photodiode |
Photodiode |
| Read Position |
Top reading |
90 degree |
| Wavelength Selection |
Snap-in Fluorescence Optical Kits |
Snap-in Fluorescence Modules (user installable) |
| Wavelengths |
UV (Ex 365 nm: Em 410 - 460 nm)
Blue (Ex 490 nm: Em 510 - 570 nm)
Green (Ex 525 nm: Em 580 - 640 nm)
Red (Ex 625 nm: Em 660 - 720 nm)
AFC (Ex 405 nm: EM 495 - 505 nm) |
UV (Ex 365 nm: Em 410 - 450 nm)
Blue (Ex 460 nm: Em 515 - 570 nm)
Green (Ex 525 nm: Em 580 - 640 nm)
Red (Ex 625 nm: Em 660 - 725 nm)
UV-GFP (Ex: 365 nm, Em: 515 - 570 nm) |
| Detection Limit |
0.5 fmol/200 µl or 1 ppt of fluorescein in 96-well plate, 30 pg/well dsDNA using DNA Quantation Dye |
6 ppt fluorescein, 450 pg/ml DNA using DNA Quantation Dye |
| Linear Dynamic Range |
6 logs, assay dependent |
6 logs, assay dependent |
| Read Out |
Relative Fluorescence Units, Direct Concentration |
Fluorescence Standard Units, Direct concentration |
| Calibration |
|
1 to 5 point calibration |
| Discrete Sample Averaging |
Sample readings are averaged over 0.5 second to improve accuracy |
Sample readings are averaged over 5 seconds to improve accuracy |
| Light Source |
LED |
LED |
| Detector |
Large-area photodiode |
Photodiode |
| Spectral Range |
450 - 750 nm |
400 - 800 nm |
| Wavelengths for Installed Filters |
450, 560, 600, 750 nm, 2 slots for customization |
560 nm, 600 nm, 750 nm |
| Photometric Measuring Range |
0 - 5.0 OD |
0 - 4.0 OD |
| Linear Dynamic Range |
0 - 4.0 OD, assay dependent |
0 - 2.5 OD, assay dependent |
| OD Accuracy |
0.01 OD ± 3% at ≤ 2.5 OD |
±0.7% |
| OD Precision |
0.01 OD ± 1% |
±0.5% at 1.0 OD |
| Stray Light |
0.002% at 560 nm in clear bottom, black wall plate |
Not Applicable |
| Light Source |
Xenon Lamp |
Not Applicable |
| Detector |
Photodiode |
Not Applicable |
| Spectral Range |
200 - 1100 nm |
Not Applicable |
| Wavelengths for Installed Filters |
260, 280, 450, 560, 600, 750 nm (2 slots customizable) |
Not Applicable |
| Photometric Measuring Range |
0 - 4.0 OD |
Not Applicable |
| Linear Dynamic Range |
0 - 3.5 OD, assay dependent |
Not Applicable |
| OD Accuracy |
0.05 OD ± 3% at ≤ 2.5 OD |
Not Applicable |
| OD Precision |
0.002 ± 3% |
Not Applicable |
| Stray Light |
0.001% at 560 nm in clear bottom, black wall plate |
Not Applicable |
| User Interface |
Built-in PC, touch screen navigation and operation |
Touch screen navigation and operation |
| Data Output |
PC compatible ASCII text file format exported to USB flash drive, or connect to PC (not included) through USB or Serial Port |
Data displayed on screen or connect to PC (not included) via serial cable to download. Optional thermal printer available |
| External PC Requirements |
Windows XP or higher |
Windows XP SP2 or later |
| Computer Interface |
USB type B or RS-232 port |
100% ASCII format through a 9-pin RS-232 serial cable at 9600 baud |
| Power |
100 - 240 VAC, 50 - 60 Hz |
Instrument: 12V DC, 0.7A Max, AC Adapter: 100-240V AC, 50/60Hz, 0.3A |
| Auto-Shutoff |
Touch screen hibernates after 15 minutes of inactivity |
Touch screen hibernates after 15 minutes of inactivity |
| Application Notes |
View Application Notes |
View Application Notes |
| Frequently Asked Questions |
Read Frequently Asked Questions |
Read Frequently Asked Questions |
| Ask Us a Question |
Contact Us |
Contact Us |
| Find a Distributor |
Distribution Map |
Distribution Map |
 |
 |
 |